• This end connectors range is used for the connection of leading in cables to electrical equipment terminals (cutouts, electronic meters, ect). It is a universal solution to connect the connection cable and the meter terminals no matter what is the metal or the block nature. The end connector can be fitted on sectoral or circular-shaped copper or aluminum stranded or solid core conductors. It provides class II protection using the double insulated colored tail, when equipped with the cover.
  • These preinslated lugs with mechanical tightening are used to connect aerial aluminum or copper conductors, solid or stranded round core, to copper equipment terminals. They are to be used without mechanical load. They are made of tinned copper which allows compatibility to copper and aluminium. The connection of the conductor is ensured by one or two shear head screws, for optimal tightening.
  • This material made of hot dip galvanised steel is designed to fix anchoring and suspension clamps.
  • The anchoring assembly is used for single or double dead-ending of A.B.C (aerial bundled conductors) with insulated neutral messenger. Two different sections of neutral messenger are available: 54.6mm² and 70mm²
  • These connectors are used to make a tap connection between aerial networks. The connection is realised by means of insulation piercing technology.
  • The pulley is designed to receive low voltage A.B.C. (Aerial Bundled Conductors) for unwinding and pulling operations. The mechanical winch is designed to pull conductors of a low voltage power line. Light and small, it can be used for all types of cable adjustments, in particular on top of supports. It can be used also for lifting loads, stowing poles and other applications. The overhead comealong clamp is designed to pull, retain and stretch bare or insulated conductors of a power line. Three models are available according to the type of conductors to be implemented: - Bare steel or aluminium cable, - A.B.C. (Aerial Bundled Conductors) type neutral messenger, - A.B.C. type fully supported. The wire-strainer is designed to pull conductors on a low voltage electrical line manually. These climbers are designed to help fitters climbing along poles and facilitate work at height. Sold in pair.
  • These equipment aim to protect the fitter from falls during installation works at height.
  • This cable sealing end is designed to ensure the watertightness of network and service stripped conductors ends. It is slid on the conductors and implemented without using flame. This cap is designed to ensure the watertightness of network and service cables conductors end. It can be used on cable drums. It is used exclusively without power.
  • The sleeve is designed to ensure watertightness and insulation of bare fittings on low voltage network cables. It is designed for round or sectoral type conductors. The sheath is used to insulate the neutral conductor. Before the installation, lubricate the bare neutral conductor.
  • This material made of hot dip galvanised steel is designed to fix anchoring and suspension clamps.
  • These connectors are used to make a tap connection between aerial networks. The connection is realised by means of insulation piercing technology.
  • This heat-shrinkable material is designed for low voltage applications in order to protect conductors and make them watertight. It is characterised by its insulating performances and its high resistivity to pollution and UV. It is retracted by blow torch heating.
  • The stainless steel SMART buckle can be used without any special tools: a pair of pliers and a hammer are sufficient. Installation is quick and easy. It can be used for service anchoring system but also for accessories such as ducts, signage, etc. on all types of poles. The yokes and buckles are used to close the strap once it is strapped around the pole. The protection tape and eyes can be used for the implementation of stainless steel strap. These stainless steel buckles are fixed onto the strap to prevent climbing on the pole and the fraud attempt.
  • DIN cabinets exist in 3 widths and are designed to receive a 300, 450 or 600mm REMIC set of bars support. They use "common" equipment (direct connection network, service) and RRCP cutting / protection network connection modules. They are also designed for possible re-supply of the set of bars support without additional re-supply doors.
  • Cable

    1,00
    This cable is used pour earth systems. It is available in bare copper or insulated copper.
  • The tool set U804 provides various tools required for the connection of the underground incoming and outgoing cables to the REMIC emergency junction box.
  • The "C" shape connectors and jumper clamps are designed to connect two conductors. The mechanical and electrical connection is ensured thanks to crimping (U009) or thanks to a mechanical tightening wich can be removed (U020). The copper connector is designed to fix up an installation in case the conductor has been severed. The stainless steel fastening allows the product to be buried. The connector L260 is equipped with a shear head. The stainless steel kit comprises two tubular lugs (U030) as well as a nut and a bolt. It is designed to disconnect the earth system in order to perform earth resistance measurements. The cutting blade is designed to open the earth system during earth resistance measurements. It is rather used inside for a residential installation. The copper round terminal lug is used to connect bare copper conductors to copper terminals.
  • The energy manager configuration is performed through a software available on PC or tablet. The last ten settings are kept in memory for a better suscriber follow up.
  • The anchoring assembly is designed for the 1500daN single or double anchoring of A.B.C. (Aerial Bundled Conductors) with insulated neutral messenger of 54.6 and 70mm² sections. It comprises a bracket supporting one or two anchoring clamps. The suspension assembly is designed for suspending the low voltage A.B.C. (Aerial Bundled Conductors) with insulated neutral messenger of 50 - 95mm² sections for code K277 and 50 - 70mm² sections for code K283. It comprises a movable link system, a suspension clamp and a bracket. 2 standard suspension assemblies are available: - ES 1500, - ESF 715 equipped with a fuse element (breaking 715 ± 65daN). The fuse element can be factory calibrated between 500 and 1 200daN. It is designed to break when an abnormal effort is applied on the A.B.C. The cable drops without causing the pole to break (i.e.: tree falling on to a power line). The cable can be quickly put back in position thanks to the installation of a new clamp on the bracket still in place.
  • The service cable dismountable sleeve is designed to establish the connection between the aerial service cable to the customer cable with Al or Cu conductors. This sleeve is used in no mechanical load situation. The box is installed on the façade of the customer building. It includes service cable dismountable sleeves to connect the aerial service cable to the customer premise.
  • These toolings are designed to realise connections.
  • The cutout sleeve makes it possible to secure the connection of the phase conductor and to protect the installation against electrical faults that may occur during illegal connections on the concentric cable. This cutout sleeve can receive a 22×58 fuse up to 100A or a neutral tube. The fraud preventing connector is used to make a tap connection between aerial networks. Once implemented, this connector cannot be dismantled. The accessories allow the anchoring of the concentric cable, both at the top of the pole and at the bottom of the meter. The U508 anchoring clamp accepts single and three-phase cables, while the K310 accepts only single-phase cables.
  • Seal

    1,00
    The seal is designed to be installed on electrical equipment, water meters, gas meters, etc. The breaking of the link enables to highlight a potential fraud. The sealable screw cover is designed to seal a screw.
  • The cable saddle (facade) is designed for fixing the low voltage A.B.C. (Aerial Bundled Conductors) on façades using neutral messenger or fully supported technology. A cable saddle is implemented every 30cm to ensure excellent fixing of the A.B.C. The wall mounting is quick and easy to implement. It is discreet and aesthetic. The cable saddle (pole) is used to fix cable trunking on poles. It is fixed using a strap and it is made of UV protected thermoplastic material. The N733 is sealed with a cable tie for 15 to 30mm diameter cables, the N734 for 30 to 50mm diameter cables, and the N735 for 50 to 90mm cables.
  • This preinsulated sleeve is designed for the junction of low voltage overhead insulated conductors to other ones. The junction can be establish between two conductors of equal or unequal sections. All combinations of sections are possible.
  • This stainless steel strap and this range of installation tools is designed to fix the suspension or anchoring clamp brackets on all types of poles (wooden, metal or concrete).
  • This stainless steel strap is mainly used to fix the suspension or anchoring clamp brackets on all types of poles (wooden, metal or concrete).
  • This connector is designed to connect a low voltage A.B.C. (Aerial Bundled Conductors) network to another network of the same type.
  • This connector is designed to connect the insulated service conductors to the low voltage A.B.C. (Aerial Bundled Conductors).
  • This Gang Fuse Switch Disconnector (FSD) is a multi-phase device. It is installed at the top of a pole or on façade. It protects the overhead connection supplying one or more multi-phase customers, or, the low voltage circuit of a pole mounted transformer. It is designed to receive 160A fuse cartridge or 240A solid connecting links, size 00 (according to the IEC 269-2.1 standard).
  • This Fuse Switch Disconnector (FSD) is a single phase device. It is installed at the top of pole or on façade. It protects the overhead connection supplying an individual customer and the low voltage network. It is designed to receive a neutral tube or 100A maximum, size 22x58 fuse cartridge (according to the IEC 269-2.1 standard).
  • This Fuse Switch Disconnector (FSD) is a single phase device. It is installed at the top of pole or on façade. It protects the overhead connection supplying an individual customer and the low voltage network. It is designed to receive a neutral tube or a 100A maximum, size 22x58 fuse cartridge (according to the IEC 269-2.1 standard)
  • This Fuse Switch Disconnector (FSD) is a single phase device. It is installed at the top of pole or on façade. It protects the overhead connection supplying an individual customer and the low voltage network. It is designated to receive a 160A fuse cartridge or 240A maximum solid connecting link size 00 (according to the IEC 269-2.1 standard).
  • This Gang Fuse Switch Disconnector (FSD) is a multi-phase device. It is installed at the top of a pole or on façade. It protects the overhead connection supplying one or more multi-phase customers, or, the low voltage circuit of a pole mounted transformer. It is designed to receive 160A fuse cartridge or 240A solid connecting links, size 00 (accordig to the IEC 269-2.1 standard).
  • This sleeve is designed to connect aluminium or copper conductors. It does not need the sectoral cores to be rounded before. It is implemented using a 13 or 17mm spanner. The electrical capacity is respectively 240mm² aluminium conductors (K191, K192), 150mm² aluminium or copper conductors (K193) and 95mm² aluminium or copper conductors (K189).
  • This preinsulated sleeve is designed for the connection of low voltage overhead insulated conductors to other ones. The junction can be established between two conductors of equal or unequal sections. All combinations of sections are possible. The section of the cables ranges from 95mm² to 150mm². The neutral conductor is dimensioned to withstand tensile strength greater than 1 530daN for the 95mm² and greater than 2 500daN for the 150mm² section.
Go to Top