• The stainless steel SMART buckle can be used without any special tools: a pair of pliers and a hammer are sufficient. Installation is quick and easy. It can be used for service anchoring system but also for accessories such as ducts, signage, etc. on all types of poles. The yokes and buckles are used to close the strap once it is strapped around the pole. The protection tape and eyes can be used for the implementation of stainless steel strap. These stainless steel buckles are fixed onto the strap to prevent climbing on the pole and the fraud attempt.
  • DIN cabinets exist in 3 widths and are designed to receive a 300, 450 or 600mm REMIC set of bars support. They use "common" equipment (direct connection network, service) and RRCP cutting / protection network connection modules. They are also designed for possible re-supply of the set of bars support without additional re-supply doors.
  • Cable

    1,00
    This cable is used pour earth systems. It is available in bare copper or insulated copper.
  • The tool set U804 provides various tools required for the connection of the underground incoming and outgoing cables to the REMIC emergency junction box.
  • The "C" shape connectors and jumper clamps are designed to connect two conductors. The mechanical and electrical connection is ensured thanks to crimping (U009) or thanks to a mechanical tightening wich can be removed (U020). The copper connector is designed to fix up an installation in case the conductor has been severed. The stainless steel fastening allows the product to be buried. The connector L260 is equipped with a shear head. The stainless steel kit comprises two tubular lugs (U030) as well as a nut and a bolt. It is designed to disconnect the earth system in order to perform earth resistance measurements. The cutting blade is designed to open the earth system during earth resistance measurements. It is rather used inside for a residential installation. The copper round terminal lug is used to connect bare copper conductors to copper terminals.
  • The energy manager configuration is performed through a software available on PC or tablet. The last ten settings are kept in memory for a better suscriber follow up.
  • The anchoring assembly is designed for the 1500daN single or double anchoring of A.B.C. (Aerial Bundled Conductors) with insulated neutral messenger of 54.6 and 70mm² sections. It comprises a bracket supporting one or two anchoring clamps. The suspension assembly is designed for suspending the low voltage A.B.C. (Aerial Bundled Conductors) with insulated neutral messenger of 50 - 95mm² sections for code K277 and 50 - 70mm² sections for code K283. It comprises a movable link system, a suspension clamp and a bracket. 2 standard suspension assemblies are available: - ES 1500, - ESF 715 equipped with a fuse element (breaking 715 ± 65daN). The fuse element can be factory calibrated between 500 and 1 200daN. It is designed to break when an abnormal effort is applied on the A.B.C. The cable drops without causing the pole to break (i.e.: tree falling on to a power line). The cable can be quickly put back in position thanks to the installation of a new clamp on the bracket still in place.
  • The service cable dismountable sleeve is designed to establish the connection between the aerial service cable to the customer cable with Al or Cu conductors. This sleeve is used in no mechanical load situation. The box is installed on the façade of the customer building. It includes service cable dismountable sleeves to connect the aerial service cable to the customer premise.
  • These toolings are designed to realise connections.
  • The cutout sleeve makes it possible to secure the connection of the phase conductor and to protect the installation against electrical faults that may occur during illegal connections on the concentric cable. This cutout sleeve can receive a 22×58 fuse up to 100A or a neutral tube. The fraud preventing connector is used to make a tap connection between aerial networks. Once implemented, this connector cannot be dismantled. The accessories allow the anchoring of the concentric cable, both at the top of the pole and at the bottom of the meter. The U508 anchoring clamp accepts single and three-phase cables, while the K310 accepts only single-phase cables.
  • Seal

    1,00
    The seal is designed to be installed on electrical equipment, water meters, gas meters, etc. The breaking of the link enables to highlight a potential fraud. The sealable screw cover is designed to seal a screw.
  • The cable saddle (facade) is designed for fixing the low voltage A.B.C. (Aerial Bundled Conductors) on façades using neutral messenger or fully supported technology. A cable saddle is implemented every 30cm to ensure excellent fixing of the A.B.C. The wall mounting is quick and easy to implement. It is discreet and aesthetic. The cable saddle (pole) is used to fix cable trunking on poles. It is fixed using a strap and it is made of UV protected thermoplastic material. The N733 is sealed with a cable tie for 15 to 30mm diameter cables, the N734 for 30 to 50mm diameter cables, and the N735 for 50 to 90mm cables.
Go to Top