• The street light set is designed to interconnect a network with a street light installation inside a lighting column. The end cap is designed to ensure street light conductor insulation when fitted at its end. It is mainly used on the bottom of lighting column.
  • Cable tie

    1,00
    The cable tie is designed to tighten the phase and neutral conductors in order to achieve correct installation. It is used to prevent the conductors from rubbing against accessories such as clamps.
  • The cable saddle (facade) is designed for fixing the low voltage A.B.C. (Aerial Bundled Conductors) on façades using neutral messenger or fully supported technology. A cable saddle is implemented every 30cm to ensure excellent fixing of the A.B.C. The wall mounting is quick and easy to implement. It is discreet and aesthetic. The cable saddle (pole) is used to fix cable trunking on poles. It is fixed using a strap and it is made of UV protected thermoplastic material. The N733 is sealed with a cable tie for 15 to 30mm diameter cables, the N734 for 30 to 50mm diameter cables, and the N735 for 50 to 90mm cables.
  • This heat-shrinkable material is designed for low voltage applications in order to protect conductors and make them watertight. It is characterised by its insulating performances and its high resistivity to pollution and UV. It is retracted by blow torch heating.
  • Bare lug

    1,00
    The tubular lug is designed to connect cable. It is made of tinplated copper (by electrolysis). It is manufactured with an inspection hole and socketing. It is implemented with hexagonal compressed connection. It allows copper and aluminium conductors. This lug meets the requirement of the NFC 20-130 standard. The friction welded lug is used to connect aluminium bare conductors to copper equipment terminals. It is used for industrial or indoor applications. This lug is implemented by crimping and out of traction. This lug meets the requirement of the NF C 63-061 standard. The Al/Cu tinned aluminium lug is used to connect aluminium bare conductors to copper equipment terminals. It is applied with a deep crimping.
  • This material made of hot dip galvanised steel is designed to fix anchoring and suspension clamps.
  • This flexible end cap is designed to ensure insulation of the end of a conductor. It can be used inside and outside.
  • This preinsulated lug is designed to connect low voltage overhead insulated conductors to copper equipment terminals. The cable sections range from 16 to 150mm² for the spin-welded terminal lug and 16 to 150mm² for the crimped lug.
  • This preinsulated sleeve is designed for the connection of copper or aluminium stranded core overhead insulated conductors with traction or with no mechanical load. It is used for the installation, repair or modification of low voltage service lines. The junction can be established between two conductors of equal or unequal sections. All combinations of sections are possible. The section of the cables ranges goes from 6 up to 35mm².
  • This preinsulated sleeve is designed for the connection of stranded core aerial service cables (aluminium or copper) to aluminium solid core sub-surface service cables. It is also used to connect aluminium solid core service cables to one another. Cable sections up to 25mm² can be connected on the stranded core side and up to 35mm² on the solid core side.
  • The service cable dismountable sleeve is designed to establish the connection between the aerial service cable to the customer cable with Al or Cu conductors. This sleeve is used in no mechanical load situation. The box is installed on the façade of the customer building. It includes service cable dismountable sleeves to connect the aerial service cable to the customer premise.
  • This preinsulated sleeve is designed for the connection of insulated conductors of a low voltage overhead network to other ones. The junction can be established between two conductors of equal or unequal sections. All combinations of sections are possible. The section of the cables ranges from 16mm² to 95mm². The neutral conductor is dimensioned to withstand tensile strength greater than 1 600daN for the 54mm² section and greater than 2 000daN for the 70mm² section.
Go to Top